Showing results: 181 - 195 of 646 items found.
-
SE-UDPS -
Salland Engineering
Load boards for applications like mixed signal, analog and RF require active components. To drive these active components multiple utility power supplies are needed. The SE-UDPS from Salland Engineering is an economical way of adding more utility power supplies to your Advantest™ V93K to drive op-amps, buffers, relays and switches. The SE-UDPS extends the usefulness of your current fleet of V93Ks. You can also minimize the need to add external power supplies on your load boards.
-
Pickering Interfaces Ltd.
Pickering's PXI high power general purpose switch modules provide a range of high current handling relays suited for high power applications. Lower current versions require one 3U PXI slot, the highest current versions occupy two slots. These modules can be used to switch heavy AC or DC loads and the highest current versions are particularly suitable for automotive test. We also have high power switches available in multiplexer and matrix configurations.
-
SERIES 62 & 63 -
Pickering Electronics
ungsten switches with power rating of 50 Watts maximum? Three switch types:5kV stand-off, 3.5kV switching10kV stand-off, 7.5kV switching15kV stand-off, 12.5kV switching? Series 62 has push-on connectors on top face for EHT and solder pins and nylon studs on the underside for PCB mounting
-
72-6792 -
Tenma
*Electronically locates hidden cables gas and water pipes*Traces hidden ceiling joists and wall studs*Senses presence of mains power withut touching live wires*Locates breaks in circuits and cables*Identifies faulty plugs switches and sockets*Incorporates audio signal and indicator light
-
SCS -
Dwyer Instruments Inc.
The Series SCS Low Cost Current Switches are ideal for monitoring whether fans, pumps, or motors are operating. The current flowing through the core of the device powers the circuit without an external power supply. All models have a built in solid state output and are easy to install. Optional LED's and 10 Amp relay modules are available. The Series SCS is available in both Split and Solid Core configurations
-
40-680-001 -
Pickering Interfaces Ltd.
Based on FET switches, the multiplexers have no wear out mechanism and include fault protection that ensures the multiplexer automatically disconnects when PXI power is not applied. Available configurations for the 40-680 range vary from a single 160 to 1 MUX to a 20-bank, 8 to 1 MUX in a single PXI module.
-
40-680-003 -
Pickering Interfaces Ltd.
Based on FET switches, the multiplexers have no wear out mechanism and include fault protection that ensures the multiplexer automatically disconnects when PXI power is not applied. Available configurations for the 40-680 range vary from a single 160 to 1 MUX to a 20-bank, 8 to 1 MUX in a single PXI module.
-
40-680-405 -
Pickering Interfaces Ltd.
Based on FET switches, the multiplexers have no wear out mechanism and include fault protection that ensures the multiplexer automatically disconnects when PXI power is not applied. Available configurations for the 40-680 range vary from a single 160 to 1 MUX to a 20-bank, 8 to 1 MUX in a single PXI module.
-
40-680-002 -
Pickering Interfaces Ltd.
Based on FET switches, the multiplexers have no wear out mechanism and include fault protection that ensures the multiplexer automatically disconnects when PXI power is not applied. Available configurations for the 40-680 range vary from a single 160 to 1 MUX to a 20-bank, 8 to 1 MUX in a single PXI module.
-
40-680-005 -
Pickering Interfaces Ltd.
Based on FET switches, the multiplexers have no wear out mechanism and include fault protection that ensures the multiplexer automatically disconnects when PXI power is not applied. Available configurations for the 40-680 range vary from a single 160 to 1 MUX to a 20-bank, 8 to 1 MUX in a single PXI module.
-
40-680-404 -
Pickering Interfaces Ltd.
Based on FET switches, the multiplexers have no wear out mechanism and include fault protection that ensures the multiplexer automatically disconnects when PXI power is not applied. Available configurations for the 40-680 range vary from a single 160 to 1 MUX to a 20-bank, 8 to 1 MUX in a single PXI module.
-
40-680-004 -
Pickering Interfaces Ltd.
Based on FET switches, the multiplexers have no wear out mechanism and include fault protection that ensures the multiplexer automatically disconnects when PXI power is not applied. Available configurations for the 40-680 range vary from a single 160 to 1 MUX to a 20-bank, 8 to 1 MUX in a single PXI module.
-
40-680-006 -
Pickering Interfaces Ltd.
Based on FET switches, the multiplexers have no wear out mechanism and include fault protection that ensures the multiplexer automatically disconnects when PXI power is not applied. Available configurations for the 40-680 range vary from a single 160 to 1 MUX to a 20-bank, 8 to 1 MUX in a single PXI module.
-
Dow-Key Mircowave Corporation
Space-qualified multi-position switches are sometimes used during launch, which means that they need to be operational under very harsh conditions, such as continuous RF power during actuation (‘hot switching’), as well as high levels of shocks and vibrations. Dow-Key has proven designs on numerous programs such as ORION, VENICE, and AMOS.
-
V210 -
Highland Technology, Inc.
The V210 is a single-wide, 6U VME module that includes 64 SPDT relays and drivers. User-settable DIP switches set the A16/A24 VME address mode, VME address, and select whether the relays are statically operated or operate in latching mode, where relay states are sustained when VME crate power is off.